;========================= GSD file: CTLS076D.GSD ===================== ; ;DEVICE NAME: P-CPATTLS ;DEVICE REVISION: V1.0 ;VENDOR NAME: EL-O-Matic ;GSD REVISION DATE: 28-Apr-2003 ; ;====================================================================== #Profibus_DP GSD_Revision = 3 Vendor_Name = "EL-O-Matic" Model_Name = "P-CPATTLS EL-O-MATIC" Revision = "1.0" Ident_Number = 0x076D Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "1.0" Software_Release = "1.0" Bitmap_Device = "CTLS76D" 31.25_supp = 1 45.45_supp = 1 93.75_supp = 1 MaxTsdr_31.25 = 100 MaxTsdr_45.45 = 250 MaxTsdr_93.75 = 1000 Redundancy = 0 Repeater_Ctrl_Sig = 0 24V_Pins = 0 Freeze_Mode_supp = 1 Sync_Mode_supp = 1 Set_Slave_Add_supp = 1 Min_Slave_Intervall = 250 Fail_Safe = 1 Modular_Station = 1 Max_Module = 10 Max_Input_Len = 100 Max_Output_Len = 100 Max_Data_Len = 200 Slave_Family = 12 Max_Diag_Data_Len = 14 Max_User_Prm_Data_Len = 3 Ext_User_Prm_Data_Const(0) = 0x00, 0x00, 0x00 ;----------- Description of extended DP features: --------------------- ; ;DPV1_Slave = 1 ;C2_Read_Write_supp = 1 ;C2_Max_Data_Len = 128 ;C2_Read_Write_required = 1 ;C2_Max_Count_Channels = 2 ;Max_Initiate_PDU_Length = 52 ;C2_Response_Timeout = 4000 ;DPV1_Data_Types = 0 ;----------- Description of device related diagnosis: --------------------- Unit_Diag_Bit(16) = "- ERROR APPEARS" Unit_Diag_Bit(17) = "Error disappears" Unit_Diag_Bit(24) = "No communication with FieldQ" Unit_Diag_Bit(28) = "EEPROM integrity test failed" Unit_Diag_Bit(30) = "- DEVICE NOT INITIALIZED" Unit_Diag_Bit(31) = "Self calibration failed" Unit_Diag_Bit(32) = "Zero point error" Unit_Diag_Bit(39) = "Ident_Number violation" Unit_Diag_Bit(37) = "Maintenance required" Unit_Diag_Bit(55) = "- EXTENSION AVAILABLE" ;------------------------------------------------------------------------------ ;Modules for Discrete Output Module = "SP_D" 0xA1 1 EndModule Module = "SP_D+RB_D" 0xC1,0x81,0x81,0x83 2 EndModule Module = "SP_D+CB_D" 0xC1,0x81,0x82,0x92 3 EndModule Module = "SP_D+RB_D+CB_D" 0xC1,0x81,0x84,0x93 4 EndModule ; Modules for modulating output Module = "Setpoint modulating" 0x81,0x81,0x00 5 EndModule Module = "SP+RB modulating" 0xC1,0x81,0x81,0x01 6 EndModule Module = "SP modulating + CB" 0xC1,0x81,0x82,0x02 7 EndModule Module = "SP+RB modulating + CB" 0xC1,0x81,0x84,0x03 8 EndModule Module = "RB positioning" 0x41,0x81,0x30 9 EndModule ; Special modules Module = "FIELDQ status2 (local op status)" 0x41,0x00,0x10 10 EndModule Module = "Control type (in & out)" 0xC1,0x00,0x00,0x11 11 EndModule Module = "Temperature (degrees)" 0x41,0x00,0x12 12 EndModule Module = "Temperature (fahrenheit)" 0x41,0x00,0x13 13 EndModule Module = "AI1" 0x41,0x81,0x14 14 EndModule Module = "AI2" 0x41,0x81,0x15 15 EndModule Module = "Cycle time open & close" 0x41,0x83,0x20 16 EndModule Module = "Break time open & close" 0x41,0x83,0x21 17 EndModule Module = "Counter opened" 0x41,0x81,0x22 18 EndModule Module = "Counter closed" 0x41,0x81,0x23 19 EndModule Module = "Travel count" 0x41,0x83,0x24 20 EndModule Module = "Travel count limit (read)" 0x41,0x83,0x25 21 EndModule Module = "Actuator recognition" 0x81,0x80,0x26 22 EndModule Module = "Init cmd + Init status" 0xC1,0x00,0x00,0x27 23 EndModule