; ============================= ; GSD-File Gateway PROFIBUS-DP ; JUMO IMAGO 500 ; Release 22.07.2002 ; ============================= ; ; #Profibus_DP GSD_Revision = 2 ;extended GSD-file is supported ; ;according to PNO directrive of 14.12.95 Vendor_Name = "MK Juchheim" ;name of the manufacturer Model_Name = "IMAGO 500 JUMO" ;name of the DP-instrument Revision = "Ausgabestand 2.0" ;actual edition of the DP-instrument Ident_Number = 0x0629 ;exact type designation of the DP-instrument Protocol_Ident = 0 ;protocol characteristica PROFIBUS-DP Station_Type = 0 ;DP-Slave FMS_supp = 0 ;DP-instrument only Hardware_Release = "1.00" ;actual edition of the hardware Software_Release = "2.00" ;actual edition of the software ; ;the following baudrates are supported 9.6_supp = 1 ; 9.6 kBaud 19.2_supp = 1 ; 19.2 kBaud ; ; 31.25 kBaud (PA) 45.45_supp = 1 ; 45.45 kBaud 93.75_supp = 1 ; 93.75 kBaud 187.5_supp = 1 ; 187.5 kBaud 500_supp = 1 ; 500 kBaud 1.5M_supp = 1 ; 1.5 MBaud 3M_supp = 1 ; 3 MBaud 6M_supp = 1 ; 6 MBaud 12M_supp = 1 ; 12 MBaud ; MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 ; ; 31.25 kBaud (PA) MaxTsdr_45.45 = 60 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 350 MaxTsdr_12M = 800 ; Redundancy = 0 ;no redundant transmission Repeater_Ctrl_Sig = 1 ;Plug signal CNTR-P TTl-level 24V_Pins = 0 ;Plug signals M24V and P24 V not connected Implementation_Type = "SPC3" ;Application of ASIC SPC3 ; ; ; ;*** Slave specific values *** Freeze_Mode_supp = 0 ;Freeze-mode is not supported Sync_Mode_supp = 0 ;Sync-mode is not supported Auto_Baud_supp = 1 ;Automatic recognition of baudrate Set_Slave_Add_supp = 1 ;Set_Slave_Add is supported Min_Slave_Intervall = 6 ;Slave-Interval = 0.6 ms Modular_Station = 1 ;Modular station Max_Module = 13 Max_Diag_Data_Len = 6 ; Slave_Family = 5 ; ; ; ; ;*** Parameterization *** ; ;This lines are for locating PBC file, and initial data length. ;Do not disturb!!! ;@PBC_File = C:\APP\JUMO\GSDGEN\14401XX\E\ju_i500.PBC ;@INIT_LEN = 2 ; User_Prm_Data_Len = 52 User_Prm_Data = 0x00, 0x03, 0x06, 0x06, 0x13, 0x00, 0xCE, 0x04, 0x13, 0x00, \ 0xD2, 0x04, 0x13, 0x00, 0xD4, 0x04, 0x11, 0x09, 0x9E, 0x02, 0x13, \ 0x08, 0x3C, 0x04, 0x11, 0x01, 0x7A, 0x02, 0x23, 0x00, 0xCE, 0x04, \ 0x23, 0x08, 0x3C, 0x04, 0x21, 0x01, 0x7A, 0x02, 0x21, 0x01, 0xBB, \ 0x02, 0x21, 0x01, 0xBC, 0x02, 0x21, 0x01, 0xBD, 0x02 Max_Input_Len = 21 Max_Output_Len = 16 Max_Data_Len = 37 ;==================== Input Master ======================================== Module = "Interface Mode" 0x10 Preset = 1 Endmodule Module = "ller/Controller1/Actual setpoint" 0x13 Preset = 1 Endmodule Module = "oller/Controller1/Output heating" 0x13 Preset = 1 Endmodule Module = "oller/Controller1/Output cooling" 0x13 Preset = 1 Endmodule Module = "Binary/Timersignals 0x099E" 0x11 Preset = 1 Endmodule Module = "Setpoints/Controller1/Setpoint 1" 0x13 Preset = 1 Endmodule Module = "Commands/Setpoint switching R1" 0x11 Preset = 1 Endmodule ;==================== Output Master ======================================== Module = "ller/Controller1/Actual setpoint" 0x23 Preset = 1 Endmodule Module = "Setpoints/Controller1/Setpoint 1" 0x23 Preset = 1 Endmodule Module = "Commands/Setpoint switching R1" 0x21 Preset = 1 Endmodule Module = "Programstart/Start hour" 0x21 Preset = 1 Endmodule Module = "Programstart/Start minute" 0x21 Preset = 1 Endmodule Module = "Programstart/Start second" 0x21 Preset = 1 Endmodule