;\**************************************************************************/ ;\* KLAY INSTRUMENTS B.V. */ ;\************************************************************************ */ ;\* GSD-file for: */ ;\* 2000PA Level transmitter */ ;\* Profibus PA Profile V3.01 */ ;\* Klay Instruments b.v. */ ;\* Author: M.M. van de Belt */ ;\* Date: 12-10-2005 */ ;\* */ ;\* DPV1-implementation: MSAC2_read/write */ ;\* Revision 0.1 */ ;\**************************************************************************/ ;/*******************************Algemeen DP********************************/ #Profibus_DP GSD_Revision = 3 Vendor_Name = "Klay Instruments b.v." Model_Name = "2000PA Level KLAY" Revision = "V3.01" Ident_Number = 0x0A29 Protocol_Ident = 0 ;Profibus DP Station_Type = 0 ;DP Slave FMS_supp = 0 ;No mixed FMS/DP Hardware_Release = "V2.0" Software_Release = "V2.0" 31.25_supp = 1 45.45_supp = 1 93.75_supp = 1 MaxTsdr_31.25 = 100 MaxTsdr_45.45 = 250 MaxTsdr_93.75 = 1000 Redundancy = 0 ;No redundancy support Repeater_Ctrl_SIg = 0 Implementation_Type = "SPC4/i-tec" 24V_Pins = 0 Bitmap_Device = "KL0a29_N" Bitmap_Diag = "KL0a29_D" Bitmap_SF = "KL0a29_S" Freeze_Mode_supp = 1 Sync_Mode_supp = 0 Set_Slave_Add_supp = 1 Min_Slave_Intervall = 250 User_Prm_Data_Len = 3 User_Prm_Data = 0, 0, 0 Modular_Station = 1 Max_Module = 2 Max_Input_Len = 10 Max_Output_Len = 0 Max_Data_Len = 10 Max_Diag_Data_Len = 14 Slave_Family = 12 Unit_Diag_Bit(16) = "Error appears" Unit_Diag_Bit(17) = "Error disappears" Unit_Diag_Bit(24) = "Hardware failure electronics" Unit_Diag_Bit(25) = "Hardware failure mechanics" Unit_Diag_Bit(26) = "Motor temperature too high" Unit_Diag_Bit(27) = "Electronic temperature too high" Unit_Diag_Bit(28) = "Memory error" Unit_Diag_Bit(29) = "Measurement failure" Unit_Diag_Bit(30) = "Device not initialized" Unit_Diag_Bit(31) = "Device initialization failed" Unit_Diag_Bit(32) = "Zero point error" Unit_Diag_Bit(33) = "Power supply failed" Unit_Diag_Bit(34) = "Configuration invalid" Unit_Diag_Bit(35) = "Restart" Unit_Diag_Bit(36) = "Coldstart" Unit_Diag_Bit(37) = "Maintenance required" Unit_Diag_Bit(38) = "Characteristics invalid" Unit_Diag_Bit(39) = "Ident_Number violation" Unit_Diag_Bit(55) = "Extension Available" DPV1_Slave = 1 C1_Read_Write_supp = 0 ;No MS1 C2_Read_Write_supp = 1 ;MS2 C2_Max_Data_Len = 128 C2_Response_Timeout = 4000 C2_Read_Write_Required = 1 C2_Max_Count_Channels = 1 Max_Initiate_PDU_Length = 52 ;--- Description of physical interface for async. and sync. transmission: --- Physical_Interface = 0 ; RS-485 Standard Copper Transmission_Delay_45.45 = 0 Reaction_Delay_45.45 = 0 Transmission_Delay_93.75 = 0 Reaction_Delay_93.75 = 0 End_Physical_Interface ; Physical_Interface = 1 ; IEC61158-2 Transmission_Delay_31.25 = 0 Reaction_Delay_31.25 = 0 End_Physical_Interface Module = "Level Value" 0x42,0x84,0x08,0x05 1 EndModule Module = "Level Value (short)" 0x94 2 EndModule Module = "Proces Temp Value" 0x42,0x84,0x08,0x05 3 EndModule Module = "Proces Temp Value (short)" 0x94 4 EndModule Module = "Empty" 0x00 5 EndModule