<?xml version="1.0" encoding="iso-8859-1"?>
<!-- edited with XML Spy v4.4 U (http://www.xmlspy.com) by Müller, Andreas (Phoenix Contact GmbH & Co) -->
<ISO15745Profile xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.profibus.com/GSDML/2003/11/DeviceProfile ..\XSD\GSDML-DeviceProfile-v1.0.xsd">
	<ProfileHeader>
		<ProfileIdentification>PROFINET Device Profile</ProfileIdentification>
		<ProfileRevision>1.00</ProfileRevision>
		<ProfileName>Device Profile for PROFINET Devices</ProfileName>
		<ProfileSource>PROFIBUS Nutzerorganisation e. V. (PNO)</ProfileSource>
		<ProfileClassID>Device</ProfileClassID>
		<ISO15745Reference>
			<ISO15745Part>4</ISO15745Part>
			<ISO15745Edition>1</ISO15745Edition>
			<ProfileTechnology>GSDML</ProfileTechnology>
		</ISO15745Reference>
	</ProfileHeader>
	<ProfileBody>
		<DeviceIdentity DeviceID="0x0003" VendorID="0x00B0">
			<InfoText TextId="Inline Busanschaltung für PROFINET IO"/>
			<VendorName Value="Phoenix Contact GmbH"/>
		</DeviceIdentity>
		<DeviceFunction>
			<Family MainFamily="I/O"/>
		</DeviceFunction>
		<ApplicationProcess>
			<DeviceAccessPointList>
				<DeviceAccessPointItem ID="DIM 1" FixedInSlots="0" PhysicalSlots="0..63" MinDeviceInterval="128" ModuleIdentNumber="0x00000300" DNS_CompatibleName="FL-IL-BK" ImplementationType="NetArm" ObjectUUID_LocalIndex="1">
					<ModuleInfo>
						<Name TextId="FL IL 24 BK PN-V1.0"/>
						<InfoText TextId="Inline Busanschaltung für PROFINET IO"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2878816"/>
						<HardwareRelease Value="10"/>
						<SoftwareRelease Value="1.00"/>
					</ModuleInfo>
					<IOConfigData MaxInputLength="512" MaxOutputLength="512"/>
					<UseableModules>
						<ModuleItemRef ModuleItemTarget="1" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile" FixedInSlots="1"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="2" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="3" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="4" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="5" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="6" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="7" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="8" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="9" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="10" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="11" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="12" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="13" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="14" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="15" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="16" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="17" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="18" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="19" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="20" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="21" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="22" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="23" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="24" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="25" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="26" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="27" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="28" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="29" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="30" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="31" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="32" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="33" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="34" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="35" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="36" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="37" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="38" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="39" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="40" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="41" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="42" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="43" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="44" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="45" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="46" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="47" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="48" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="49" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="50" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="51" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="52" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="53" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="54" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="55" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="56" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="57" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="58" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="59" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="60" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="61" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="62" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="63" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="64" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="65" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="66" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="67" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="68" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="69" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="70" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="71" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="72" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="73" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="74" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="75" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="76" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="77" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="78" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="79" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="80" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="81" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="82" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="83" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="84" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="85" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="86" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="87" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="88" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="89" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="90" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="91" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="92" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="93" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="94" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="95" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="96" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="97" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="98" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="99" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="100" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="101" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="102" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="103" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="104" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="105" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="106" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
						<ModuleItemRef AllowedInSlots="2..63" ModuleItemTarget="107" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile"/>
					</UseableModules>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="DIM 1" SubmoduleIdentNumber="0x00000001">
							<IOData IOCS_Length="1" IOPS_Length="1"/>
							<RecordDataList>
								<ParameterRecordDataItem Index="1" Length="2">
									<Name TextId="Alarmverhalten"/>
									<Const Data="0x01,0x00" ByteOffset="0"/>
									<Ref TextId="Diagnosealarme" Visible="true" DataType="Bit" BitOffset="0" ByteOffset="0" Changeable="true" AllowedValues="0 1" DefaultValue="1" ValueItemTarget="Diagnosealarme"/>
									<Ref TextId="ReturnOfSubmodul Alarm" Visible="false" DataType="Bit" BitOffset="0" ByteOffset="1" Changeable="true" AllowedValues="0 1" DefaultValue="0" ValueItemTarget="ReturnOfSubmodul Alarm"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
					<Graphics>
						<GraphicItemRef Type="DeviceSymbol" GraphicItemTarget="1"/>
						<!--<GraphicItemRef State="SF" GraphicItemTarget="2"/>-->
					</Graphics>
				</DeviceAccessPointItem>
			</DeviceAccessPointList>
			<ModuleList>
				<ModuleItem ID="1" ModuleIdentNumber="0x00000001">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="Inline-Master">
						<Name TextId="Inline-Master (intern)"/>
						<InfoText TextId="Integrierter Inline-Master"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="1" SubmoduleIdentNumber="0x00000001">
							<IOData IOCS_Length="1" IOPS_Length="1">
								<Input>
									<DataItem TextId="Diagnosestatusregister" DataType="Unsigned16" UseAsBits="true"/>
									<DataItem TextId="Diagnoseparameterregister" DataType="Unsigned16" UseAsBits="true"/>
									<DataItem TextId="Erweitertes Diagnoseparameterregister" DataType="Unsigned16" UseAsBits="true"/>
									<DataItem TextId="Standardfunktionsstatusregister" DataType="Unsigned16" UseAsBits="true"/>
								</Input>
								<Output>
									<DataItem TextId="Standardfunktions Startregister" DataType="Unsigned16" UseAsBits="true"/>
									<DataItem TextId="Standardfunktions Parameterregister" DataType="Unsigned16" UseAsBits="true"/>
									<DataItem TextId="Reserve Ausgangsregister1" DataType="Unsigned16" UseAsBits="true"/>
									<DataItem TextId="Reserve Ausgangsregister2" DataType="Unsigned16" UseAsBits="true"/>
								</Output>
							</IOData>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="2" ModuleIdentNumber="0x0000c2bd" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24/230 DOR 1/W"/>
						<InfoText TextId="InfoText_ID_2"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2836434"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="2" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbd,0x00,0x02" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="189" AllowedValues="189" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="2" AllowedValues="2" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="3" ModuleIdentNumber="0x0000c2bd" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24/230 DOR 1/W-PC"/>
						<InfoText TextId="InfoText_ID_3"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2860400"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="3" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbd,0x00,0x02" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="189" AllowedValues="189" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="2" AllowedValues="2" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="4" ModuleIdentNumber="0x0000c2bd" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24/48 DOR 2/W"/>
						<InfoText TextId="InfoText_ID_4"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2863119"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="4" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbd,0x00,0x02" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="189" AllowedValues="189" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="2" AllowedValues="2" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="5" ModuleIdentNumber="0x000041bd" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24/230 DOR 4/W-PC"/>
						<InfoText TextId="InfoText_ID_5"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2860413"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="5" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbd,0x00,0x04" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="189" AllowedValues="189" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="4" AllowedValues="4" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="6" ModuleIdentNumber="0x000041bd" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24/230 DOR 4/W"/>
						<InfoText TextId="InfoText_ID_6"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2836421"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="6" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbd,0x00,0x04" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="189" AllowedValues="189" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="4" AllowedValues="4" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="7" ModuleIdentNumber="0x0000c2bd" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL DO 1 AC"/>
						<InfoText TextId="InfoText_ID_7"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2836748"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="7" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbd,0x00,0x02" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="189" AllowedValues="189" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="2" AllowedValues="2" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="8" ModuleIdentNumber="0x000041bd" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL DO 4 AC-1A"/>
						<InfoText TextId="InfoText_ID_8"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2742696"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="8" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbd,0x00,0x04" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="189" AllowedValues="189" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="4" AllowedValues="4" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="9" ModuleIdentNumber="0x0000c2bd" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 DO 2"/>
						<InfoText TextId="InfoText_ID_9"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2740106"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="9" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbd,0x00,0x02" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="189" AllowedValues="189" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="2" AllowedValues="2" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="10" ModuleIdentNumber="0x0000c2bd" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 DO 2-2A"/>
						<InfoText TextId="InfoText_ID_10"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2726243"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="10" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbd,0x00,0x02" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="189" AllowedValues="189" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="2" AllowedValues="2" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="11" ModuleIdentNumber="0x0000c2bd" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 DO 2-NPN"/>
						<InfoText TextId="InfoText_ID_11"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2740119"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="11" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbd,0x00,0x02" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="189" AllowedValues="189" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="2" AllowedValues="2" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="12" ModuleIdentNumber="0x000041bf" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 EDO 2"/>
						<InfoText TextId="InfoText_ID_12"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2742599"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="12" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbf,0x00,0x04" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="191" AllowedValues="191" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="4" AllowedValues="4" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="13" ModuleIdentNumber="0x000041bd" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 DO 4"/>
						<InfoText TextId="InfoText_ID_13"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2726256"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="13" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbd,0x00,0x04" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="189" AllowedValues="189" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="4" AllowedValues="4" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="14" ModuleIdentNumber="0x000041bd" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 DO 4-ME"/>
						<InfoText TextId="InfoText_ID_14"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2863931"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="14" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbd,0x00,0x04" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="189" AllowedValues="189" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="4" AllowedValues="4" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="15" ModuleIdentNumber="0x000081bd" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 DO 8"/>
						<InfoText TextId="InfoText_ID_15"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2726269"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="15" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbd,0x00,0x08" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="189" AllowedValues="189" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="8" AllowedValues="8" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="16" ModuleIdentNumber="0x000081bd" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 DO 8-2A"/>
						<InfoText TextId="InfoText_ID_16"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2742117"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="16" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbd,0x00,0x08" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="189" AllowedValues="189" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="8" AllowedValues="8" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="17" ModuleIdentNumber="0x000081bd" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 DO 8-NPN"/>
						<InfoText TextId="InfoText_ID_17"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2863533"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="17" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbd,0x00,0x08" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="189" AllowedValues="189" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="8" AllowedValues="8" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="18" ModuleIdentNumber="0x000001bd" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 DO 16"/>
						<InfoText TextId="InfoText_ID_18"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2726272"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="18" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbd,0x00,0x10" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="189" AllowedValues="189" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="16" AllowedValues="16" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="19" ModuleIdentNumber="0x0000c2be" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 120 DI 1"/>
						<InfoText TextId="InfoText_ID_19"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2836706"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="19" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbe,0x00,0x02" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="190" AllowedValues="190" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="2" AllowedValues="2" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="20" ModuleIdentNumber="0x0000c2be" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 230 DI 1"/>
						<InfoText TextId="InfoText_ID_20"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2740342"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="20" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbe,0x00,0x02" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="190" AllowedValues="190" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="2" AllowedValues="2" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="21" ModuleIdentNumber="0x0000c2be" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 DI 2"/>
						<InfoText TextId="InfoText_ID_21"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2726201"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="21" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbe,0x00,0x02" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="190" AllowedValues="190" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="2" AllowedValues="2" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="22" ModuleIdentNumber="0x0000c2be" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 DI 2-NPN"/>
						<InfoText TextId="InfoText_ID_22"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2740112"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="22" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbe,0x00,0x02" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="190" AllowedValues="190" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="2" AllowedValues="2" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="23" ModuleIdentNumber="0x0000c2be" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 EDI 2"/>
						<InfoText TextId="InfoText_ID_23"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2742609"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="23" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbe,0x00,0x02" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="190" AllowedValues="190" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="2" AllowedValues="2" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="24" ModuleIdentNumber="0x000041be" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 EDI 2-DESINA"/>
						<InfoText TextId="InfoText_ID_24"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2740326"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="24" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbe,0x00,0x04" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="190" AllowedValues="190" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="4" AllowedValues="4" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="25" ModuleIdentNumber="0x000041be" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 DI 4"/>
						<InfoText TextId="InfoText_ID_25"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2726214"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="25" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbe,0x00,0x04" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="190" AllowedValues="190" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="4" AllowedValues="4" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="26" ModuleIdentNumber="0x000041be" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 DI 4-ME"/>
						<InfoText TextId="InfoText_ID_26"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2863928"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="26" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbe,0x00,0x04" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="190" AllowedValues="190" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="4" AllowedValues="4" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="27" ModuleIdentNumber="0x000081be" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 DI 8"/>
						<InfoText TextId="InfoText_ID_27"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2726227"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="27" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbe,0x00,0x08" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="190" AllowedValues="190" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="8" AllowedValues="8" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="28" ModuleIdentNumber="0x000081be" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 DI 8/T2"/>
						<InfoText TextId="InfoText_ID_28"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2860439"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="28" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbe,0x00,0x08" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="190" AllowedValues="190" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="8" AllowedValues="8" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="29" ModuleIdentNumber="0x000001be" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 DI 16"/>
						<InfoText TextId="InfoText_ID_29"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2726230"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="29" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbe,0x00,0x10" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="190" AllowedValues="190" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="16" AllowedValues="16" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="30" ModuleIdentNumber="0x000001be" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A digital">
						<Name TextId="IB IL 24 DI 16-NPN"/>
						<InfoText TextId="InfoText_ID_30"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2863517"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="30" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbe,0x00,0x10" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="190" AllowedValues="190" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="16" AllowedValues="16" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="31" ModuleIdentNumber="0x0000017d" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A analog">
						<Name TextId="IB IL AO 1/SF"/>
						<InfoText TextId="InfoText_ID_31"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2726298"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="31" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0x7d,0x00,0x10" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="125" AllowedValues="125" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="16" AllowedValues="16" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="32" ModuleIdentNumber="0x0000017d" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A analog">
						<Name TextId="IB IL AO 1/U/SF"/>
						<InfoText TextId="InfoText_ID_32"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2727776"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="32" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0x7d,0x00,0x10" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="125" AllowedValues="125" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="16" AllowedValues="16" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="33" ModuleIdentNumber="0x0000025b" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A analog">
						<Name TextId="IB IL AO 2/U/BP"/>
						<InfoText TextId="InfoText_ID_33"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2732732"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="33" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0x5b,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="91" AllowedValues="91" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="34" ModuleIdentNumber="0x0000025b" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A analog">
						<Name TextId="IB IL AO 2/U/BP-ME"/>
						<InfoText TextId="InfoText_ID_34"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2863957"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="34" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0x5b,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="91" AllowedValues="91" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="35" ModuleIdentNumber="0x0000025b" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A analog">
						<Name TextId="IB IL AO 2/SF"/>
						<InfoText TextId="InfoText_ID_35"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2862806"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="35" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0x5b,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="91" AllowedValues="91" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="36" ModuleIdentNumber="0x0000027f" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A analog">
						<Name TextId="IB IL AI 2/SF"/>
						<InfoText TextId="InfoText_ID_36"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2726285"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="36" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0x7f,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="127" AllowedValues="127" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="37" ModuleIdentNumber="0x0000027f" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A analog">
						<Name TextId="IB IL AI 2/SF-ME"/>
						<InfoText TextId="InfoText_ID_37"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2863944"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="37" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0x7f,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="127" AllowedValues="127" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="38" ModuleIdentNumber="0x0000027f" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A analog">
						<Name TextId="IB IL AI 2/SF-230"/>
						<InfoText TextId="InfoText_ID_38"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2740818"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="38" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0x7f,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="127" AllowedValues="127" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="39" ModuleIdentNumber="0x0000027f" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A analog">
						<Name TextId="IB IL AI 2/4-20"/>
						<InfoText TextId="InfoText_ID_39"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2860442"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="39" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0x7f,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="127" AllowedValues="127" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="40" ModuleIdentNumber="0x000002dc" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A analog">
						<Name TextId="IB IL AI 2-HART-PAC"/>
						<InfoText TextId="InfoText_ID_40"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2860264"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="40" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xdc,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="220" AllowedValues="220" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="41" ModuleIdentNumber="0x0000025f" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A analog">
						<Name TextId="IB IL AI 8/SF"/>
						<InfoText TextId="InfoText_ID_41"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2727831"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="41" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0x5f,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="95" AllowedValues="95" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="42" ModuleIdentNumber="0x0000025f" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A analog">
						<Name TextId="IB IL AI 8/IS"/>
						<InfoText TextId="InfoText_ID_42"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2742748"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="42" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0x5f,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="95" AllowedValues="95" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="43" ModuleIdentNumber="0x0000027f" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A analog">
						<Name TextId="IB IL TEMP 2 RTD"/>
						<InfoText TextId="InfoText_ID_43"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2726308"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="43" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0x7f,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="127" AllowedValues="127" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="44" ModuleIdentNumber="0x0000027f" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A analog">
						<Name TextId="IB IL TEMP 2 UTH"/>
						<InfoText TextId="InfoText_ID_44"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2727763"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="44" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0x7f,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="127" AllowedValues="127" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="45" ModuleIdentNumber="0x000081bf" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="Antrieb - Motorschalter">
						<Name TextId="IB IL 400 ELR 1-3A"/>
						<InfoText TextId="InfoText_ID_45"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2727352"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="45" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbf,0x00,0x08" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="191" AllowedValues="191" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="8" AllowedValues="8" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="46" ModuleIdentNumber="0x000081bf" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="Antrieb - Motorschalter">
						<Name TextId="IB IL 400 ELR R-3A"/>
						<InfoText TextId="InfoText_ID_46"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2727378"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="46" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbf,0x00,0x08" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="191" AllowedValues="191" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="8" AllowedValues="8" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="47" ModuleIdentNumber="0x000081bf" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="Antrieb - Motorschalter">
						<Name TextId="IB IL 400 MLR 1-8A"/>
						<InfoText TextId="InfoText_ID_47"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2727365"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="47" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbf,0x00,0x08" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="191" AllowedValues="191" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="8" AllowedValues="8" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="48" ModuleIdentNumber="0x000002bf" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A-Funktionsmodul">
						<Name TextId="IB IL CNT"/>
						<InfoText TextId="InfoText_ID_48"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2836337"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="48" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbf,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="191" AllowedValues="191" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="49" ModuleIdentNumber="0x000002bf" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A-Funktionsmodul">
						<Name TextId="IB IL INC"/>
						<InfoText TextId="InfoText_ID_49"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2836324"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="49" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbf,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="191" AllowedValues="191" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="50" ModuleIdentNumber="0x0000027f" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A-Funktionsmodul">
						<Name TextId="IB IL INC-IN"/>
						<InfoText TextId="InfoText_ID_50"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2819228"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="50" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0x7f,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="127" AllowedValues="127" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="51" ModuleIdentNumber="0x000002bf" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="Positionier-Steuerung">
						<Name TextId="IB IL SSI"/>
						<InfoText TextId="InfoText_ID_51"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2836340"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="51" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbf,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="191" AllowedValues="191" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="52" ModuleIdentNumber="0x0000025f" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A-Funktionsmodul">
						<Name TextId="IB IL SSI-IN"/>
						<InfoText TextId="InfoText_ID_52"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2819309"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="52" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0x5f,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="95" AllowedValues="95" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="53" ModuleIdentNumber="0x0000025f" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A-Funktionsmodul">
						<Name TextId="IB IL IMPULSE-IN"/>
						<InfoText TextId="InfoText_ID_53"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2819231"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="53" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0x5f,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="95" AllowedValues="95" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="54" ModuleIdentNumber="0x000002bf" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A-Funktionsmodul">
						<Name TextId="IB IL PWM/2"/>
						<InfoText TextId="InfoText_ID_54"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2742612"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="54" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbf,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="191" AllowedValues="191" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="55" ModuleIdentNumber="0x000001dc" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A-Funktionsmodul">
						<Name TextId="IB IL RS 232"/>
						<InfoText TextId="InfoText_ID_55"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2727349"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="55" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xdc,0x00,0x10" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="220" AllowedValues="220" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="16" AllowedValues="16" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="56" ModuleIdentNumber="0x000006bf" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A-Funktionsmodul">
						<Name TextId="IB IL RS 485/422-PRO"/>
						<InfoText TextId="InfoText_ID_56"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2863707"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="56" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_5" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_6" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_7" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_8" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_9" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_10" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_11" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_12" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_5" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_6" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_7" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_8" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_9" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_10" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_11" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_12" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbf,0x00,0x60" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="191" AllowedValues="191" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="96" AllowedValues="96" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="57" ModuleIdentNumber="0x000005df" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="Positionier-Steuerung">
						<Name TextId="IB IL POS 200"/>
						<InfoText TextId="InfoText_ID_57"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2819338"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="57" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_5" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_6" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_7" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_8" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_9" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_10" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_5" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_6" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_7" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_8" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_9" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_10" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xdf,0x00,0x50" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="223" AllowedValues="223" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="80" AllowedValues="80" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="58" ModuleIdentNumber="0x000002c3" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="Antrieb">
						<Name TextId="IB IL DC AR 48/10 A"/>
						<InfoText TextId="InfoText_ID_58"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2819286"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="58" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xc3,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="195" AllowedValues="195" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="59" ModuleIdentNumber="0x000003c3" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="Antrieb">
						<Name TextId="IB IL EC AR 48/10A"/>
						<InfoText TextId="InfoText_ID_59"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2819587"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="59" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_5" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_6" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_5" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_6" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xc3,0x00,0x30" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="195" AllowedValues="195" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="48" AllowedValues="48" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="60" ModuleIdentNumber="0x000002bf" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A-Funktionsmodul">
						<Name TextId="IB IL TEMPCON RTD"/>
						<InfoText TextId="InfoText_ID_60"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2819244"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="60" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbf,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="191" AllowedValues="191" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="61" ModuleIdentNumber="0x000002bf" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A-Funktionsmodul">
						<Name TextId="IB IL TEMPCON UTH"/>
						<InfoText TextId="InfoText_ID_61"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2819312"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="61" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Eingaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
								<Output Consistency="Item consistency">
									<DataItem TextId="Ausgaenge_1" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_2" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_3" DataType="Unsigned8" UseAsBits="true"/>
									<DataItem TextId="Ausgaenge_4" DataType="Unsigned8" UseAsBits="true"/>
								</Output>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbf,0x00,0x20" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="191" AllowedValues="191" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="32" AllowedValues="32" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="62" ModuleIdentNumber="0x0000c2be" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="E/A-Funktionsmodul">
						<Name TextId="IB IL 24 SAFE 1"/>
						<InfoText TextId="InfoText_ID_62"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2740782"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="62" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbe,0x00,0x02" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="190" AllowedValues="190" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="2" AllowedValues="2" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="63" ModuleIdentNumber="0x0000c2be" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="Stromversorgung">
						<Name TextId="IB IL 24 PWR IN-F-D"/>
						<InfoText TextId="InfoText_ID_63"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2836667"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="63" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbe,0x00,0x02" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="190" AllowedValues="190" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="2" AllowedValues="2" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="64" ModuleIdentNumber="0x0000c2be" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="Stromversorgung">
						<Name TextId="IB IL 24 PWR IN/2-F-D"/>
						<InfoText TextId="InfoText_ID_64"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2860280"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="64" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbe,0x00,0x02" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="190" AllowedValues="190" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="Unsigned16" ByteOffset="1" Changeable="false" DefaultValue="2" AllowedValues="2" ValueItemTarget="PD-Laengen"/>
								</ParameterRecordDataItem>
							</RecordDataList>
						</VirtualSubmoduleItem>
					</VirtualSubmoduleList>
				</ModuleItem>
				<ModuleItem ID="65" ModuleIdentNumber="0x0000c2be" xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile">
					<ModuleInfo CategoryRef="IL" SubCategory1Ref="Stromversorgung">
						<Name TextId="IB IL 24 SEG-F-D"/>
						<InfoText TextId="InfoText_ID_65"/>
						<VendorName Value="Phoenix Contact"/>
						<OrderNumber Value="2836683"/>
						<HardwareRelease Value="xx"/>
						<SoftwareRelease Value="xx"/>
					</ModuleInfo>
					<VirtualSubmoduleList>
						<VirtualSubmoduleItem ID="65" SubmoduleIdentNumber="0x00000001">
							<IOData IOPS_Length="1" IOCS_Length="1">
								<Input Consistency="Item consistency">
									<DataItem TextId="Eingaenge_1" DataType="Unsigned8" UseAsBits="true"/>
								</Input>
							</IOData>
							<RecordDataList>
								<ParameterRecordDataItem Index="45312" Length="3" TransferSequence="0">
									<Name TextId="INTERBUS Parameter"/>
									<Const Data="0xbe,0x00,0x02" ByteOffset="0"/>
									<Ref TextId="ID-Code" Visible="true" DataType="Unsigned8" ByteOffset="0" Changeable="false" DefaultValue="190" AllowedValues="190" ValueItemTarget="ID-Codes PD"/>
									<Ref TextId="PD-Laenge" Visible="true" DataType="U